CONTEX8 CONTROLLER





This instrument handles a lot of functions useful in a textile circular machine.

Counts the circular knitting machine rotations, by deducting them from the pre-set number and stopping the production when the countdown is over. It displays the revolving speed of the machine and the time required to achieve the countdown.

Measure the yarn dispensed to yarn feeders on 4 standard systems plus an additional one dedicated to Lycra. It check that measured amount fit into a programmable tolerance and stop machine if yarns consumption is out of range.

Stores the knitting times of the machine and the rotations performed during 5 work shifts, allowing to protect these data with a password that can be disabled.

Six preset messages can be actived from textile machine electrical circuit to inform the most common stop causes.

Data output on Serial Port RS232.

The device consists of a main module and of a magnetic switch to detect the circular knitting machine rotations.

It comes supplied with several fitting brackets.

The staff in charge of its operation can use the control functions, in that the access to the data is protected by a password that can be disabled.

Short-circuit protections, electrical interference suppressors and component tolerating external interference all guarantee the safe operation and greater reliability of this device.


TECHNICAL SPECIFICATIONS



Power supply voltage from 22 to 26VAC, Power consumption 5W.

Dispenser meter counter up to 99.99 meters.

Counter for 5 work shifts up to 999 hours and 99.999 rotations.

Historical counter for the overall rotations and total running hour recording meter.

Long-lasting components tolerating external interference.

External connections by means of polarized terminal boards, which can be pulled out.

Box complying with DIN 43700 standards for flush-mounting, coming supplied with specially-designed brackets.

Dimension: Height 72mm, Width 143mm, Depth 100mm

Counter up to 99.999 rotations.

2A 250V service output.